boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-317
Boards for HiPath 3000
Peripheral Boards
Contact assignment
Note:
Pinouts shown are at the board itself. The main distribution frame cable (MDF cable) sup-
plied reverses the signal order before the MDF.
Table 3-152
TMQ4 (for U.S. only) - Contact Assignment
Contact
Connector X2
Port
Contact
Connector X2
Port
1
b-wire (ring), trunk 1
1
5
b-wire (ring), trunk 3
3
2
a-wire (tip), trunk 1
6
a-wire (tip), trunk 3
3
b-wire (ring), trunk 2
2
7
b-wire (ring), trunk 4
4
4
a-wire (tip), trunk 2
8
a-wire (tip), trunk 4