HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
2-23
System Data
System-Specific Capacity Limits for HiPath 3000, HiPath 5000
1
Testing is not required on stations and lines up to the maximum configuration. Testing using the project planning tool is
mandatory for configurations which include UCD/ACD, more than one SLCN, or groups of more than 10 stations (intranet:
http://intranet.mch4.siemens.de/syseng/perfeng/tools/hpt/index.htm
).
2
Only configurations that do not exceed this limit will be supported.
3
Depending on the system configuration and performance, the specified capacity limits may not always be achieved. To
ensure that the dynamic capacity limit of HiPath 3750 or HiPath 3700 is not exceeded, the configuration can be tested
using the project planning tool (intranet:
http://intranet.mch4.siemens.de/syseng/perfeng/tools/hpt/index.htm
). Testing is
not required for configurations of up to 250 stations and 90 lines. Testing using the project planning tool is mandatory for
configurations which include UCD/ACD, more than one SLC16N, or groups of more than 10 stations.
4
Up to 96 of the 192 stations can be TDM stations.
5
Up to 61 of the 192 stations can be TDM stations (4xa/b + 1xU
P0/E
+ 7xBS/32xHiPath Cordless Office stations at the cen-
tral board + 3xSLU8R or 3x8SLAR).
6
Up to 41 of the 96 stations can be TDM stations (4xa/b + 5xU
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central
board + 1x16SLA).
7
Up to 33 of the 96 stations can be TDM stations (4xa/b + 5xU
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central
board + 1xSLU8R or 1x8SLAR).
8
These are administrative capacity limits.
9
Due to the power consumption of HG 1500, a UPSC-D must be used.
10 Due to the power consumption of HG 1500, a UPSC-DR must be used.
11 If the total number of U
P0/E
stations, analog stations and additional stations connected using an adapter is greater than
72, an external EPSU2 power supply unit must be used.
12 4xa/b + 1xU
P0/E
+ 7xBS/32xHiPath Cordless Office stations at the central board + 5xSLU8R or 5x8SLAR.
13 4xa/b + 5xU
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central board + 2x16SLA.
14 4xa/b + 5xU
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central board + 2xSLU8R or 2x8SLAR.
15 Testing using the project planning tool is not required for configurations of up to 384 analog stations, no other station types,
and 90 lines. Configurations that contain UCD/ACD or more than one SLC16N or groups with more than ten stations
should always be checked using the project planning tool (intranet:
http://intranet.mch4.siemens.de/syseng/perfeng/tools/
hpt/index.htm
).
16 4xa/b at the central board + 5x8SLAR.
17 4xa/b at the central board + 2x16SLA.
18 4xa/b at the central board + 2x8SLAR.
19 8xU
P0/E
at the central board + 1xSLMO24.
20 8xU
P0/E
at the central board + 5xSLU8R.
21 8xU
P0/E
at the central board + 2xSLU8.
22 8xU
P0/E
at the central board + 2xSLU8R.
23 The total number of U
P0/E
stations and additional stations connected using an adapter is limited to 384.
24 If the total number of U
P0/E
stations and additional stations connected using an adapter is greater than 24, a UPSC-D/
UPSC-DR must be used.
25 Due to the 5-V power supply unit, one SLC16N and a maximum of two HG 1500 V3.0 boards can be used.
26 64 HiPath Cordless Office stations at the SLC16N or 32 HiPath Cordless Office stations at the central board.
27 Two HG 1500 boards can be installed if PDM1 is not being used.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......