Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-234
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Peripheral Boards
3.3.24
STMD8
Introduction
The STMD8 (
S
ubscriber And
T
runk
M
odule
D
igital S
0
) board contains eight S
0
basic rate ac-
cesses for HiPath 3750 and HiPath 3700, which are used
●
for the S0 trunk connection (via NT) (not for U.S.)
●
for a Point-to-point or point-to-multipoint connection
●
for S0 networking (not for U.S) (CorNet N, CorNet NQ or QSig)
●
for an S0 bus for connecting ISDN telephones (not for U.S.) (separate power supply re-
quired).
Switches and LEDs
Figure 3-94
STMD8 (S30810-Q2558-X200)
H300
H301
.
.
.
.
H308
LEDs
On
S300
Lockout switch
1
:
:
8