inst_h3.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
4-59
Installing HiPath 3000
Installing HiPath 3800
Information on cable and connector assignment is provided in the board descriptions in
Chapter 3.
Closing the backplane of the system cabinets
Slot with
SLMA
SLMA2
SLMO2
CABLUs for connection between backplane (SIVAPAC connector) and
MDFU-E (jumper strip for 25 TW):
●
C39195-A7267-A372: 3 m in length, short stripped length for MDFU-E
slots 11-21 (see Figure 4-37)
●
C39195-A7267-A373: 3 m in length, long stripped length for MDFU-E
slots 1-10 (see Figure 4-37)
CABLU for connection between backplane (SIVAPAC connectors) and ex-
ternal patch panel S30807-K6143-X (SIVAPAC socket terminal strip):
●
S30267-Z333-A20: 2 m in length (refer to Figure 4-43)
●
S30267-Z333-A50: 5 m in length (refer to Figure 4-43)
Open-end cable (24 TW) for connection between backplane (SIVAPAC con-
nector) and external patch panel:
●
S30267-Z196-A150: 15 m in length
●
S30267-Z196-A250: 25 m in length
●
S30267-Z196-A350: 35 m in length
●
S30267-Z196-A550: 55 m in length
●
S30267-Z196-A950: 95 m in length
Slot with
PBXXX
A CAS cable is connected via an APPCU adapter (S30807-K5415-X).
1
for selected countries only
2
for U.S. only
>
After the cable has been connected, the backplane of the basic cabinet and that of
the expansion cabinet (if applicable) must be closed with the dummy panels provid-
ed (C39165-A7075-C44).
If
Then
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......