wclient.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
10-71
Workpoint Clients
optiPoint Accessories
10.7
optiPoint Accessories
The following data is valid for the telephone families optiset E, optiPoint 410, optiPoint 410 S,
optiPoint 420, optiPoint 420 S, optiPoint 500 and for the telephone optiPoint 600 office. Restric-
tions are indicated in the relevant places.
10.7.1
External AC Adapters
You may need an external AC adapter if you are using large configurations or if you need to
extend the range.
10.7.1.1
Local Power Supply for optiset E, optiPoint 500 and optiPoint 600 office
You can connect a local power supply to the line cords of a host or client telephone using two
MW6 jacks and the connection cable supplied (see Figure 10-32).
Variants
●
Local power supply, Euro: AUL:06D1284 (C39280-Z4-C71 = number entered on unit)
●
Local power supply, UK: AUL:06D1287 (C39280-Z4-C72 = number entered on unit)
●
Local power supply, 110 V USA: AUL:51A4827 (C39280-Z4-C73 = number entered on
unit)
Data for local power supply AUL:06D1284 (Euro)
●
Line voltage: 220 (230) Vac
●
AC line frequency: 47 ... 53 Hz
●
Output voltage: Max. 50 Vdc, min. 30 Vdc
●
Output current: Max. 250 mA
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......