Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-132
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Peripheral Boards
Switches and LEDs
Lockout switch settings
●
Pressed = free (default)
●
Not pressed = locked: existing connections remain active, new connections are locked.
–
The yellow LED lights up when all connections are ended and the board is effectively
locked.
–
The yellow LED flashes when a lockout request is entered (via lockout switch or soft-
ware) but at least one call is still active.
To reset the board to the default state, activate the lockout switch twice within the first 10 s of
board startup.
Figure 3-62
IVMS8 and IVMS8R (S30122-Q7379-X, -K7379-Z)
2
50
X1 = con-
nection to
CUC/
CUCR/
CUP/
CUPR
Lockout switch
LED (green)
LED (yellow)
X2
10
2
X4
10
2
X3 = LAN
connector,
8-pin RJ45
jack
X3
X1