Expanding and Upgrading HiPath 3000
P31003-H3560-S403-54-7620, 09/05
9-18
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
exup.fm
Expanding HiPath 3000
9.2.4.5
Expansion Cabinet Rack ECR With Batteries and EPSU2-R
If the internal system power supply unit for HiPath 3500 or HiPath 3300 does not provide
enough power for the overall telephone configuration (corded and cordless telephones), an ad-
ditional power supply is necessary. In this case, the EPSU2-R external power supply unit
should be installed in the ECR.
Figure 9-7 shows the position of the EPSU2-R inside the ECR.
The block diagram below illustrates the cable run between the EPSU2-R and the batteries in-
side the ECR and the power supply unit of the system (UPSC-DR). The connection cable be-
tween the expansion cabinet rack ECR and the system cabinet is also provided.
7
Danger
An expansion cabinet rack (ECR) equipped with an external power supply unit
(EPSU2-R) may only be operated if the housing is closed.
Before opening the housing, disconnect the ECR from the power supply by
●
setting the switches for battery voltage and line voltage on the ECR’s front panel
to "Off".
●
removing the battery fuse on the ECR front panel and
●
unplugging all power and connection cables.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......