Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-98
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Peripheral Boards
LED statuses and their meanings
Connection types
●
Fiber optic cable
The fiber optic cable is only connected via the front panel. The opto-electronic converter
must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the front
panel.
●
Copper cable
The copper cable is only connected via the 15-pin Sub-D jacks on the front panel.
Table 3-34
DIUN2 - LED Statuses
Red LED
Green
LED
Status
Action
Off
Off
Board not receiving power or not plugged in
correctly.
Board is out of order.
Check plug contact on
board.
On
Off
Board is receiving power and board test is
in progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Replace board.
Loadware loading not successfully com-
pleted. Board is faulty.
Replace board.
Error detected on board.
Board is deactivated (not applicable to er-
rors detected by test loops) or board was
deactivated using HiPath 3000 Manager E.
Check whether the board
was deactivated using Hi-
Path 3000 Manager E. If
not, replace board.
Flashing
Off
Loadware is being loaded.
Off
On
Board test completed successfully. Board is
OK (idle state).
Off
Flashing At least one channel is activated.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......