boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-159
Boards for HiPath 3000
Peripheral Boards
Table 3-66
HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS2/2 Base Stations Connected to SLC16N (Not for U.S.)
Number
of BS2/2s
on
SLC16N
Maximum number of corded telephones
analog telephones
0
1 - 10
11 - 20
21 - 30
31 - 40
41 - 50
optiset E and optiPoint 500 telephones
1
63
59
54
50
46
41
2
58
53
49
45
40
36
3
53
48
44
40
35
31
4
47
43
39
34
30
26
5
42
38
33
29
25
20
6
37
33
28
24
20
15
7
32
27
23
19
14
10
8
27
22
18
13
9
5
Table 3-67
HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS3/3 Base Stations Connected to SLC16N and BS4 connect-
ed to SLC16N (not for U.S)
Number
of BS3/3s and BS4s
connected via 2xU
P0/E
to
SLC16N
Maximum number of corded telephones
analog telephones
0
1 - 10
11 - 20
21 - 30
31 - 40
41 - 50
optiset E and optiPoint 500 telephones
1
64
60
56
51
47
42
2
60
56
52
47
43
39
3
57
52
48
43
39
35
4
53
48
44
40
35
31
5
49
44
40
36
31
27
6
45
40
36
32
27
23
7
41
37
32
28
23
19
8
37
33
28
24
20
15
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......