boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-19
Boards for HiPath 3000
Central Boards
●
Two digital S
0
interfaces (CO (default) or station)
●
Backplane (CUC or CUP) connection via slots 1 (X11), 2 (X5) and 3 (X6)
●
Music on hold: MPPI, EXM
●
Options bus (O bus)
●
Two V.24 interfaces. The second interface is implemented via the
option.
Switches and indicators
●
Reset/reload switch
–
Switch pressed < 5 s = Reset activated
–
Switch pressed > 5 s = Reload activated (RUN LED out indicates that a reload is in
progress)
●
RUN LED
LED status meaning is explained in the following table.
>
Please note that only one MPPI module may be connected. In other words, you
can connect either MPPI S30122-K5380-X200 via X4 or MPPI S30122-K7275-
B via X19/X20.
Table 3-3
CBCC - LED Status Meaning
RUN LED
Meaning
Off
No power
On
Reset switch pressed briefly
Off
Reset switch held down for more than 5 seconds (LED is extin-
guished to acknowledge that a reload has begun)
On
System boot
Off
for 0.1 s
Load operation: APS in SDRAM, loadware, and card data
Flashing
0.5 s on/0.5 s off
Normal operating state (zero load)
1
1
The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm.
Flashing
0.1 s on/0.1 s off
MMC removed or defective
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......