Installing HiPath 3000
P31003-H3560-S403-54-7620, 09/05
4-80
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
inst_h3.fm
Installing HiPath 3800
4.2.7.4
For U.S. only: Connecting Network Facilities
Connecting to the Point of Demarcation
Most main distribution frames are designed with a network demarcation block. You must cross-
connect the MDF to the incoming trunks. Use a standard wiring tool for laying the cable wires.
Connecting to T1, PRI, or CorNet
Secondary Protection
7
DANGER
Ground the system properly before connecting the stations.
7
Caution
The TMST2 Module can only be installed in conjunction with a listed channel service
unit CSU.
7
DANGER
To protect against surge voltage caused by lightning, the following boards require
secondary protection when their lines leave the building where the main distribution
frame is housed:
●
DIU2U*
●
SLMA / SLMA8
●
TMC16
●
TMDID
●
TMEW2
●
TM2LP
* When this module is connected to the public network, secondary protection must
be provided by the CSU.