inst_h3.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
4-13
Installing HiPath 3000
Installing HiPath 3800
4.2.3.3.4
Setting Up a Two-Cabinet System Side by Side
Procedure
7
Caution
To guarantee sufficient ventilation in the system cabinets, allow a minimum clear-
ance of 50 mm between the base of the cabinets and the ground.
Step
Activity
1.
Place the system cabinet in the installation site and make sure that it is level and
stable.
2.
Check that the space between the base of the basic cabinet and the ground is at
least 50 mm.
3.
If necessary, set up the basic cabinet in the following way:
●
Unscrew lock nut (Figure 4-1, A) on one of the cabinet feet using an open-end
wrench (wrench size = 13 mm).
●
Adjust the height of the cabinet foot by turning the screw nut (Figure 4-1, B)
so that the cabinet is steady and the minimum clearance is observed.
●
Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A).
4.
Place the expansion cabinet beside the basic cabinet.
Note: The cabinets can be placed directly beside one another.
5.
Check that the space between the base of the expansion cabinet and the ground
is at least 50 mm.
6.
If necessary, set up the expansion cabinet as described in Step 3 ensuring that
both cabinets are at exactly the same level.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...