Starting Up HiPath 3000
P31003-H3560-S403-54-7620, 09/05
5-14
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
start_h3.fm
Starting Up HiPath 3750 and HiPath 3700
Procedure: Reinitialization
Proceed as follows if measures to expand the system configuration require reinitialization of the
numbering plan:
Step
Activity
Description
1.
Disconnect the system from
the power supply. Check that
the system is de-energized.
Expand as required.
2.
Connect system to power sup-
ply
A continuous numbering plan is generated (as was
the case when the system was first initialized).
Notes:
●
Changes to the extension numbers result in
changes to the individual, extension-specific
data.
●
Only those ports provided for in accordance
with the maximum configuration are activated if
the maximum line configuration is exceeded
(too many trunk boards).
●
A mixture of subscriber line circuits and trunk
lines on one STMD8 can result in gaps in line
numbering. This is because all STMD8 ports
are initially activated as trunks and are only
subsequently reconfigured.