exup.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
9-11
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
Table 9-3
EPSU2-R - Explanation of Display and Connecting Elements
LED [6]
(DC output)
LED [7]
(AC input)
Description
On
On
DC output and AC input voltages are OK.
Off
On
No DC voltage at output
(for example DC load short-circuited).
On
Off
No AC voltage at input
(power failure or system powered by batteries, including addition-
al power).
Off
Off
No AC input voltage (power outage) and batteries are empty, or
the EPSU2-R fuse is defective or was removed (by turning to the
left).