inst_h3.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
4-77
Installing HiPath 3000
Installing HiPath 3800
4.2.7.3.1
Installing the S
0
Patch Panel in the 19-Inch Cabinet
Installation Procedure
Insert the S
0
patch panel (A, in Figure 4-45) above a system cabinet and secure it to the 19-
inch frame on both the left and the right using two screws (B) on each side.
7
Caution
The patch panel must be installed above the system cabinet.
A minimum of one height unit must be kept clear above the cabinet to guarantee suf-
ficient ventilation of the system cabinet. This is achieved by the gray plastic cover
fixed to the top of the system cabinets. Never remove this plastic cover.
Figure 4-45
Installing the External S
0
Patch Panel in the 19-Inch Cabinet
A
B