
boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-89
Boards for HiPath 3000
Central Boards
Figure 3-38
Connections between the BSG 48/38 Battery Cabinet and UPSM (HiPath
3750, HiPath 3700)
Lamp wire connector (UPSM
res
)
Contact (max. 100 mA) closes when battery mode is activated. A relay con-
nected in series can be used for signaling purposes, for example.
UPSM
100 - 240 Vac
50 - 60 Hz
UPSM
UPSM
Expansion cabi-
net 2
100 - 240 Vac
50 - 60 Hz
100 - 240 Vac
50 - 60 Hz
DC
Output 1,
–48 V
1
2
3
BSG 48/38
with batt.set
(38 Ah/48 V)
100 - 240 Vac
50 - 60 Hz
AC input
HiPath 3750/HiPath 3700
(For reasons of clarity, the cabinets
are shown separately and without
grounding.)
to UPSM
to BSG 48/38
DC connection cable
(S30122-X5950-F310)
DC connection cable
DC connection cable
DC connection cable
AC power
USVI (battery box)
BC
AC power
USVI (battery box)
Expansion cabi-
net 1
AC power
USVI (battery box)
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......