HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
4-15
Installing HiPath 3000
Installing HiPath 3800
4.2.3.4
Grounding the System
Ground the system as described.
4.2.3.4.1
Not for U.S.: Grounding the System
Grounding: Grounding options
The illustrations starting with Figure 4-6 show different grounding options.
Note on possible ground loops
7
Danger
Each HiPath 3800 system cabinet and all external main distribution frames (for ex-
ample, MDFU-E) must be grounded as shown in Figure 4-5 by a separate ground
conductor (minimum cross-section = 2.5 mm
2
). Make sure that the ground conductor
is securely installed and strain-relieved.
If external factors can impact on the ground conductor and if protected installation is
not possible, the ground conductor must have a minimum cross-section of 4 mm
2
.
Failure to follow these instructions can result in electrical shock.
7
Danger
If your personnel are not qualified to work on the low-voltage network (230 Vac), you
must hire a licensed electrician to ground the system separately using option 1b
(Figure 4-7).
>
To avoid ground loops from remotely operated devices (V.24 system peripherals),
the devices should be connected to the same low-voltage network (sub-distribution
board) if possible.
If the building floor plan does not permit this, you may need a line driver to isolate
the external devices in the event of a malfunction.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......