service.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
12-39
Service
Guided Maintenance
You can configure these areas independently of one another by marking the area and selecting
Operation/Properties
:
●
The maximum log size (in KB) and the reaction if this value is exceeded are defined under
"General". 1.44 MB (= capacity of a floppy disk) is the recommended log size. "Overwrite
events where necessary" is the recommended setting.
●
You can select an event source under "Filter" for example, to display only the entries for the
HiPath 5000 server. You can further restrict the output under Category and Event ID.
Evaluating events
Double-click an entry in an Event Viewer area to obtain more precise information on an event.
Use the two arrow buttons to spring from one event to the next.
The HiPath 5000 Server entries in Table 12-8 are currently supported.
Saving the event file (log file)
If problems occur within the customer network, you can save an Event Viewer area as an event
log (log file) and then forward this file to the relevant Service Support personnel for further di-
agnosis.
Always save an eventlog (log file) in evt file format (file extension
*.evt
). The Event Viewer
can only read and configure the file if it is in this format.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......