3.3.18
SLU8
Introduction
The SLU8 board for HiPath 3550 and HiPath 3350 (wall housing) with 8 digital subscriber line
interfaces allows up to 16 digital telephones to be connected in host-client operation (master-
slave operation).
Interfaces
Figure 3-82
SLU8 Interfaces (S30817-Q922-A301)
7
Caution
After deactivating the power supply, you must wait a short while before plugging the
SLU8 in or out. If you do not wait before doing so, the CBCC/CBCP may be dam-
aged.
Table 3-96
SLU8 Contact Assignments
Contact
X2 (U
Po/E
ports 1-4)
X3 (U
P0/E
ports 5-8)
1
a 1
a 5
2
b 1
b 5
3
a 2
a 6
4
b 2
b 6
5
a 3
a 7
6
b 3
b 7
7
a 4
a 8
8
b 4
b 8