Installing HiPath 3000
P31003-H3560-S403-54-7620, 09/05
4-116
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
inst_h3.fm
Installing HiPath 3750, HiPath 3700
Connection cables between the “8-slot” basic and expansion cabinets
If installing a multi-cabinet system, you must also connect the cables between the BC and ECs.
X98
EC1
EC2
1 SU connector each (16 TW) to MDFU or MDFU-E
X29 - X89
All
1 SU connector each (8 TW) to MDFU or MDFU-E (not for S
2M
)
X99
EC1
EC2
1 SU connector each (8 TW) to MDFU or MDFU-E (not for S
2M
)
If
Then
Two-cabinet
System
Connect BC to EC1 = 2 cables (S30267-Z178-A13)
(see Figure 4-66)
Three-cabinet
System
●
Connect BC to EC1 = 2 cables (S30267-Z178-A13)
●
Connect BC to EC2 = 2 cables (S30267-Z178-A13)
(see Figure 4-67)
Table 4-12
Jack Assignment on the “8-Slot” Backplane
Connec-
tor
Cabinet
Function