Guided Maintenance
3
Error in CRC checksum
–
Check transferred APS
version and re-transfer
APS.
If error is still present, re-
place MMC module.
4
Return to old APS, default CDB loaded
–
5
Return to old APS, old CDB loaded
–
6
APS Transfer disconnect
–
Transfer APS again
7
Country data successfully transferred
–
–
8
Error occurred when deleting old APS on
MMC
–
Transfer APS again.
If error is still present, re-
place MMC module.
9
Block length error during APS transfer
–
Transfer APS again
10
Remaining length error during APS trans-
fer
–
Transfer APS again
Error Class B-16 - General Errors
1
Error in pool administration (rel_pool_ele)
Hard restart
Notify appropriate service
support
2
Error in pool administration
(get_trans_store)
Hard restart
3
Error in pool administration
(get_trans_store)
Hard restart
4
Error during COSMOS send call
Hard restart
5
Error during COSMOS timer call
Hard restart
6
Error during COSMOS receive call
Hard restart
7
COSMOS records error (recovery)
Hard restart
8
Error while handling real-time clock
–
9
Watchdog error
Hard restart
10
Manual hard restart
–
–
11
Manual reload
–
–
12
System had no voltage
–
Notify appropriate service
support
13
Automatic customer data backup (CDB
backup) not performed
–
14
Unidentified hard restart
–
–
Table 12-7
HiPath 3000 Class B Error Messages
No.
Meaning
Action
Recovery
Action
Technician
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......