Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-58
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Central Boards
Front view of LUNA2 with indicators and switches
●
LED for displaying the operating status:
–
Illuminated = LUNA2 is operating as power supply unit
–
Flashing = LUNA2 is operating as a battery charger
–
Off = At least one secondary operating voltage is outside the tolerance zone. In this
case
a) the voltage feed for LUNA2 may not be sufficient (an additional LUNA2 module is
required. For information on how to calculate the number of LUNA2 modules required,
see Page 3-62).
b) LUNA2 may be defective (the board must be replaced).
Figure 3-19
LUNA2 Front Panel
Switches for setting the operating mode
ON/OFF switch for secondary operating voltag-
es (system supply voltages)
LUNA2 can only be plugged in or out when
the system is switched off (switch = DC-OFF)
LED for displaying the operating status
Removal tab
You can use a screwdriver here to remove the
LUNA2 from the shelf.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......