Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-168
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Peripheral Boards
Installation notes
●
The EPSU2 AC/DC converter is designed for installation indoors only.
●
The unit is suitable only for mounting on the wall (vertically, with AC port on bottom).
●
Always install the units in a dry, dust-free area where there is no danger of vibrations.
●
Always make sure there is sufficient air circulation around the units. Do not block the ven-
tilation holes.
●
When selecting the location, keep in mind the necessary lengths of the following cables:
– AC cable (grounding plug, IEC 320 socket)
– DC cable to UPSC-D, length = 2 m
Procedure: EPSU2 wall-mounting
Step
Activity
1.
Drill two holes for anchors (5 mm in diameter) in the wall, as shown in Figure 3-76.
Depending on the wall materials, you may have to use a different kind of attach-
ment, such as wood screws for timber walls.
2.
Insert the anchors and insert two screws (3.5 mm in diameter), leaving 5 mm pro-
jecting from the wall.
3.
Mount the EPSU2 onto the screws and tighten them all the way.
Figure 3-76
EPSU2 - Holes for Mounting on the Wall
115 mm
102 mm
33 mm
317 mm
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......