HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-295
Boards for HiPath 3000
Peripheral Boards
3.3.33
TMDID (for U.S. only)
Introduction
The TMDID board (
T
runk
M
odule
D
irect
I
nward
D
ialing) provides direct inward dialing from the
central office (CO) to HiPath 3800.
The board has eight trunk circuits that connect to analog trunks.
The circuits can be set up for immediate start or wink start.
Switches
●
Switches for manual trunk selection. In this case, all trunks are filtered one after the other
until the LED of the desired trunk flashes.
●
Lockout switch which can be used to manually block the selected trunk circuit.
LED statuses and their meanings
>
The peripheral board slots on the HiPath 3800 are fitted with SIPAC 9 SU connec-
tors. Since the TMDID board has SIVAPAC connector strips, you will have to install
a SIVAPAC-SIPAC board adapter in order to be able to use it in HiPath 3800.
For information on upgrade procedures, please see Section 4.2.5.4.
Table 3-137
TMDID (For U.S. Only) - LED Statuses
LED status
0 - 7
Meaning
Off
The trunk circuit is free.
On
The trunk circuit is assigned.
Slow flashing
The trunk circuit was deactivated by the software.
Fast flashing
The switch was pressed and the trunk circuit was selected for manual acti-
vation or deactivation.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......