4.2.3.3.3
Stacking Two Cabinets
Procedure
7
Caution
To guarantee sufficient ventilation for the system cabinets, comply with the following
requirements:
●
The basic cabinet must be set up as the bottom cabinet.
●
Allow a minimum of 50 mm clearance between the base of the cabinet and the
floor, and between basic and expansion cabinets.
Step
Activity
1.
Place the system cabinet in the installation site and make sure that it is level and
stable.
2.
Check that the space between the base of the basic cabinet and the ground is at
least 50 mm.
3.
If necessary, set up the basic cabinet in the following way:
●
Unscrew lock nut (Figure 4-1, A) on one of the cabinet feet using an open-end
wrench (wrench size = 13 mm).
●
Adjust the height of the cabinet foot by turning the screw nut (Figure 4-1, B)
so that the cabinet is steady and the minimum clearance is observed.
●
Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A).
4.
Place the expansion cabinet on top of the basic cabinet.
The cabinet feet have indents. When placing the expansion cabinet on top of the
basic cabinet, ensure that these indents are sitting precisely on top of the screw
heads in the four corners of the basic cabinet (Figure 4-2).
5.
Check that the space between the base of the basic cabinet and the ground is at
least 50 mm.
6.
If necessary, set up the expansion cabinet as described in Step 3.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......