inst_h3.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
4-171
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Procedure for mounting the MDFU on the wall
Layout and dimensions of the MDFU
Step
Activity
1.
Use the template to drill the holes.
2.
Insert the wall anchors and screw in the screws, leaving 5 mm projecting.
3.
Remove the housing cover and mount the MDFU-E on the brackets.
4.
Tighten the screws through the holes.
Figure 4-95
MDFU - Layout and Dimensions (367.0 x 328.8 x 125.4 mm) (not for U.S.)
2 x PFT1
or
1 x PFT4
9 slots (9 x 30 mm)
Special built-in comps.
System side
Line network
328.8
36
7.0
1
2
3
6
4
5
Jumpering