Expanding and Upgrading HiPath 3000
P31003-H3560-S403-54-7620, 09/05
9-2
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
exup.fm
Expanding HiPath 3000
9.2
Expanding HiPath 3000
The following section provides information on supplementary equipment or extensions that are
not described in
Chapter 4, “Installing HiPath 3000”
9.2.1
Replacing Peripheral Boards for HiPath 3800
HiPath 3800 lets you remove and insert peripheral boards during operation (hot plugging). The
following startup rules apply.
Rules for removing and inserting boards
7
Caution
Always wear an antistatic wristband when working on the system (especially when
handling boards).
7
Caution
To ensure that the system operates without blocking, you must follow the rules in
Section 4.2.5 concerning board configuration.
Table 9-1
Startup Rules for Inserting and Removing Boards
If
Then
Inserting new board
in free slot
Board is integrated into the system according to the rules for initial
startup (Section 4.2.5.5).
●
System with default numbering plan
The station numbers from the new board are appended (consec-
utively and in ascending order) to the numbers already assigned.
●
System with modified numbering plan
The station numbers on the new board can be in any order.
Using HiPath 3000 Manager E or Assistant T, you can assign a spe-
cific station to a port. If the number is already assigned to a different
object, you can switch both numbers.
Replacing board with
same or under
equipped board type
Board is activated. The same station range is used.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......