Starting Up HiPath 3000
P31003-H3560-S403-54-7620, 09/05
5-12
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
start_h3.fm
Starting Up HiPath 3750 and HiPath 3700
5.3.2
Supplying the System with Power
Procedure
HiPath 3750 and HiPath 3700 RUN LED
The CBCPR has a RUN LED that indicates the system status.
Step
Activity
1.
Plug in the power supply cable on the power supply unit(s).
2.
Monitor the Run LED of the CBCPR. The individual steps of the system boot
(Table 5-6) can be observed this way.
Table 5-6
RUN LED - LED Status Meaning
RUN LED
Meaning
Off
No power
On
Reset switch pressed briefly
Off
Reset switch held down for more than 5 seconds (LED is extinguished
to acknowledge that a reload has begun)
On
System boot
Off
for 0.1 s
Load operation: APS in SDRAM, loadware, and card data.
Flashing
0.5 s on/0.5 s off
Normal operating state (zero load)
1
1
The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm.
Flashing
0.1 s on/0.1 s off
MMC removed or defective
>
The HiPath 3750 or HiPath 3700 is ready when the date “1. JAN 00” and the time
“00:00” appear in the display on the system telephone.
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......