boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-145
Boards for HiPath 3000
Peripheral Boards
3.3.11
SLA8N (not for U.S.), SLA16N, SLA24N
Introduction
The peripheral boards
●
SLA8N (
S
ubscriber
L
ine
A
nalog) with eight analog T/R interfaces (not for U.S.)
●
SLA16N (16 analog interfaces)
●
SLA24N (24 analog interfaces)
can be used in HiPath 3750, HiPath 3550 and HiPath 3700.
Switches and LEDs
The operating mode (short or long line with the appropriate flash times) can be set up for each
subscriber line interface with HiPath 3000 Manager E (the menu Settings: Set up station –>
Station –> Parameters –> Flags).
Figure 3-70
SLA8N (not for U.S.), SLA16N, SLA24N (S30810-Q2929-X200, -X100, -X)
H1 (green)
H2 (red)
LEDs
Lockout switch S1
(position = free, factory default)