358
PD31 OTST
(■)
DO communication control contact status(HEX):
If DO is controlled by parameter, PD31 can
determine DO contact status(6 contacts). Bit0~Bit5
corresponds to DO1~DO6.
0=DO contact is off.
1=DO contact is on.
Note, you can refer to PD25 setting.
Turret
mode
0000h
0000h
~
003Fh
N/A
PD32
SDLY
(*)
Servo ON delay time when SON is ON.
This parameter is to set the delay time of SERVO ON
when the SON is ON.
All
0
0
~
3000
msec
PD33 SFDO Software DO register
The bit0 ~ bit7 of this parameter setting controls DO
signal S_DO0 ~ S_DO7 separately.
All 0000h
0000h
~
00FFh
N/A
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...