160
(Note) DI signal
Valid torque limit value
TL1
TL
0
0
PA05 setting
0
1
TLA > PA05 setting => PA05 setting
TLA < PA05 setting => TLA
1
0
PC25 setting > PA05 setting => PA05 setting
PC25 setting < PA05 setting => PC25 setting
1
1
TLA > PC25 setting => PC25 setting
TLA < PC25 setting => TLA
Note 0: OFF(TLx-SG is open-circuited) 1: ON (TLx-SG is short-circuited)
When the generated torque of the servo motor reaches the torque limit value setting by the
PA05, PC 25 or the analog torque limit, TLC -SG will be conductive and TLC is digital output.
Name
Parameter
abbreviation
Description
Control
mode
Torque
limiting
control
TLC
When the generated torque reaches the torque
value setting by the Inner torque limit 1(PA05) or the
analog torque limit(TLA), TLC -SG will be
conductive. TLC-SG will not be conductive when
SON is off.
Pt,Pr,S
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...