423
0x0106
The 6th alarm in the past
1word
0x0107
The 7th alarm in the past
1word
0x0108
The 8th alarm in the past
1word
0x0109
The 9th alarm in the past
1word
0x010A
The 10th alarm in the past
1word
0x010B
Alarm
occurrence
time(low word)(PG05)
1word
0x010C
Alarm occurrence time(high word)(PG06)
1word
0x010D
1st alarm record occurrence time(low word)(PG07)
1word
0x010E
1st alarm record occurrence time(high word) (PG08)
1word
0x010F
2nd alarm record occurrence time(low word) (PG09)
1word
0x0110
2nd alarm record occurrence time(high word)(PG10)
1word
0x0111
3rd alarm record occurrence time(low word)(PG11)
1word
0x0112
3rd alarm record occurrence time(high word)(PG12)
1word
0x0113
4th alarm record occurrence time(low word)(PG13)
1word
0x0114
4th alarm record occurrence time(high word)(PG14)
1word
0x0115
5th alarm record occurrence time(low word)(PG15)
1word
0x0116
5th alarm record occurrence time(high word)(PG16)
1word
0x0117
6th alarm record occurrence time(low word)
1word
0x0118
6th alarm record occurrence time(high word)
1word
0x0119
7th alarm record occurrence time(low word)
1word
0x011A
7th alarm record occurrence time(high word)
1word
0x011B
8th alarm record occurrence time(low word)
1word
0x011C
8th alarm record occurrence time(high word)
1word
0x011D
9th alarm record occurrence time(low word)
1word
0x011E
9th alarm record occurrence time(high word)
1word
Note: returning 0x00ff means no alarm, returning 0x0001 means AL.01 occurs, returning
0x0012 means AL.12 occurs, and so on.
(4) Alarm data clearance (readable and writable)
Communication
address
Content
Data
length
0x0130
If “0x1EA5” is written to this address, it will clear current
alarm.
When reading this address, it will return current alarm.
The setting range is 0~0xFFFF.
1word
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...