333
No
Abbr.
Parameter function and description
PC88
CSDS
Command
code 000Ch
Change engaged X position: rotates in forward direction until
disengagement condition is met
General
parameter
N/A
Macro
parameter
PC84=new master axis engaged X position(unit: pulse number
of master axis)
1.
This macro command can change the engaged position immediately even
when the E-Cam is engaged, and it will also automatically calculate the remaining
engaged length and disengage the E-Cam after rotating one cycle (360
°
) in the
forward direction. At that time, only E-Cam is disengaged , and you should set
the disengagement condition PC66.u=2,4,6 to complete this operation.
2.
E-Cam disengages when an alarm occurs or power supply is cut off. If you
want E-Cam to re-engage at the last disengaged position and continue its
remaining cycle, it is recommended that you record the master axis position(X) of
the last disengagement and then execute this macro command.
3.Note that when E-Cam is disengaged, the servo position might shift slightly,
causing position error when E-Cam re-engages.
When E-Cam rotates one cycle, pulse
number of master axis: (PC62/PC61)
Sl
a
v
e
p
o
s
iti
o
n
Assigned new position PC84
Remaining
engaged length
(auto calculation)
Master axis position (X)
Note: when using this macro command, it is recommended that you execute the
macro command before operating the master axis.
Failure code
F0C1h
when this macro command is executed, E-Cam is not in engaged
status
Failure code
F0C2h
PC84 data is wrong, the value cannot be less than 0.
Failure code
F0C3h
PC84 data is wrong, it has to be less than the value of
(PC62/PC61)
Success code
100Ch
-
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...