38
Inner
torque
limit
option
TL1
When TL1 is on, inner torque limit 2 (parameter setting2)
will be valid.
Input signal
Valid torque limit value
TL1
TL
0
0
Parameter setting of PA05.
0
1
If TLA > PA05 setting => PA05 is valid.
If TLA < PA05 setting =>TLA is valid.
1
0
If PC25 setting > PA05 setting => PA05 is
valid.
If PC25 setting < PA05 setting => PC25 is
valid.
1
1
If TLA > PC25 setting => PC25 is valid.
If TLA < PC25 setting => TLA is valid
ALL
Speed
option 1
SP1
Speed control mode: which is to select the speed
command. When SP3 is used, make it valid by setting
internal parameters
Parameter
setting
Input signal
Speed
command
SP3 SP2 SP1
When
speed
option
(SP3) is not
used.
(initial
status)
0
0
Speed analog
command
(VC)
0
1
Inner speed
command 1
1
0
Inner speed
command 2
1
1
Inner speed
command 3
When
speed
0
0
0
Speed analog
command
S,
T
Speed
option 2
SP2
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...