507
will be released automatically when ABSM is turned on.
(1)
Timeout check when ABSR data requested signal is off.
After the ABST ready signal is on, if the ABSR data requested signal is not turned on
within 5 seconds, [AL.17 ABS timeout warning] will occur.
(2)
Timeout check when ABSR data requested signal is on.
After the ABST ready signal is off, if the ABSR data requested signal is not turned off
within 5 seconds, [AL.17 ABS timeout warning] will occur.
(3)
Timeout check after the ABSM transmission mode is completed.
After the ABS data transfer is completed and ABST ready signal is turned on, if the ABSM
is not turned off within 5 seconds, [AL.17 ABS timeout warning] will occur.