90
Motor feedback
pulse number
(low 5-digit)
(after E-Gear ratio)
FPL.O
pulse
Motor feedback pulse number (low 5-
digit)(after E-Gear ratio)
Ex: if the value is 123456789 pulse, it
displays 56789 (Note 1).
-99999
~99999
Input number of
pulse commands
(high 5-digit)
(after E-Gear ratio)
CPH.O pulse
Input number of pulse commands (high
5-digit) (after E-Gear ratio)
If the value is 123456789 pulse, it
displays 1234 (Note 1).
-21474
~21474
Input number of
pulse commands
(low 5-digit)
(after E-Gear ratio)
CPL.O
pulse
Input number of pulse commands (low 5-
digit) (after E-Gear ratio)
If the value is 123456789 pulse, it
displays 56789 (Note 1).
-99999
~99999
Deviation pulse
number
(after E-Gear ratio)
E. O
pulse
Deviation number between command
input pulse and feedback pulse (after E-
Gear ratio)
It displays the last 5 digits of the actual
value.
-99999
~99999
Command input
pulse frequency
CPF
kHz
External command input pulse
frequency.
-6000
~6000
Current motor speed
r
rotary
motor
rpm
linear
motor
mm/s
Displays current motor feedback speed.
-6000
~6000
Analog speed
command/limit
voltage
F
V
(1)
Speed mode: it displays the input
voltage of analog speed command.
(2)
Torque mode: it displays the input
voltage of analog speed limit.
-10.00
~+10.00
Speed input
command/limit
V
rotary
motor
rpm
linear
motor
mm/s
(1)
Speed mode: it displays analog input
speed command.
(2)
Torque mode: it displays analog input
speed limit.
-6000
~6000
Analog torque
command/limit
voltage
U
V
(1)
Position mode, speed mode: it
displays voltage of analog torque limit
(TLA)
0 ~ +10.00
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...