219
Interrupt command(INS):
it can be applied in any control type, and it is always be set in the
latter program. PR mode of SDP servo provides internal INS and external INS.
1.Internal INS:
which is a sequential command with interrupt setting in the latter program. The
biggest difference from the sequential command is the definition of the delay time. The delay
time of sequential commands is calculated from when the target position or target speed is
reached, but internal INS is calculated from the beginning of the former program, as shown in
the following example.
PATH#12(AUTO positioning control, incremental positioning path: 10485760 pulse, target
speed: 600 rpm, delay time: 1500 ms, ACC: 200 ms, DEC: 200 ms) → PATH#13(Positioning
control, with INS command, incremental positioning path: -10485760 pulse, target speed: 600
rpm, delay time: 0 ms, ACC: 200 ms, DEC: 200 ms).
The execution result of this program is shown in the figure below, and the internal interruption
helps the entire control program to manage time easily.
The delay time of internal INS should not be less than the completion time of the program,
otherwise it will interrupt by the latter program before the former program is completed, as
shown in the figure below:
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...