417
9.4 Write and read communication parameters.
(1)
Status monitor(Read-only)
Communication
address
Content
Data
length
0x0000
Motor feedback pulses (after E-Gear ratio) [pulse]
2word
0x0002
Input number of pulse commands (before E-Gear
ratio)[pulse]
2word
0x0004
Number of pulses error(after E-Gear ratio) [pulse]
2word
0x0006
Pulse command input frequency [Hz]
2word
0x0008
The value of communication address 0x0235 determines
its content.
Setting
value
!=2
➔
Motor
current
speed[rpm]
Setting
value
=2
➔
Motor
current
speed[mm/s]
2word
0x000A
Analog speed command/limit voltage [V] (Display 2
decimal point)
2word
0x000C
The value of communication address 0x0235 determines
its content.
Setting value !=2
➔
speed command /limit [rpm]
Setting value =2
➔
speed command /limit [mm/s]
2word
0x001E
Analog torque command/limit voltage [V] (Display 2
decimal point)
2word
0x0010
Torque input command/limit [%]
2word
0x0012
Effective load ratio [%]
2word
0x0014
Peak load ratio [%]
2word
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...