281
rotation speed >= CDS setting.
x=5: perform gain switching when CDP is OFF.
x=6: perform gain switching when position
command frequency <= CDS setting
x=7: perform gain switching when position error
pulse <= CDS setting
x=8: perform gain switching when servo motor
rotation speed <= CDS setting
PB12
CDS Gain switching condition value
The set value of the CDS (kpps, pulse, rpm) is
varied according to CDP setting, and its unit is
depended on the switching item.
Pt,
Pr,
S
10
0
~
400000
0
kpps
pulse
rpm
mm/s
PB13
CDT Gain switching time constant
The CDT is used to smooth the gain switching,
and it is used to set the time constant when
switching the CDP and CDS conditions.
Pt,
Pr,
S
1
0
~
1000
ms
PB14
GD2 Servo motor load inertia ratio 2
This parameter is to set ratio of load inertia to
motor inertia, which is only valid during gain
switching.
Pt,
Pr,
S
70
0
~
1200
0.1
time
0.1kg
PB15
PG2 Position loop gain change ratio
This parameter is to set position loop gain change
ratio, and it’s valid only after the auto tuning
function is disabled.
Pt,
Pr
100
10
~
500
%
PB16
VG2 Speed loop gain change ratio
This parameter is to set speed loop gain change
ratio, and it’s valid only after the auto gain tuning
function is disabled.
Pt ,
Pr,
S
100
10
~
500
%
PB17
VIC2 Speed integral gain change ratio
This parameter is to set speed integral gain
change ratio, and it’s only valid after the auto gain
tuning function is disabled.
Pt,
Pr,
S
100
10
~
500
%
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...