457
Drive Model Type
SDP-□□□A2C
010
020
040
075
100
150
200
300
Servo Motor type
SME-□□□□
L005
L010
L020
L040
L075
L100
L150
L200
L300
--
--
--
--
M100
M150 M200
M300
--
H020
H040
H075
H085
--
--
H130 H180
Motor capacity
50W
200W
400W
750W
1.0KW
1.5KW 2KW
3.0KW
100W
850W
1.3KW 1.8KW
D
igit
al
inp
ut
/ou
tpu
t
Digital Input
Servo on, forward and reverse rotation limit , pulse deviation elimination,
torque direction option, speed command selection, position command
selection, forward and reverse rotation command, proportional control
switching, torque limit switching, alarm reset, emergency stop, control mode
switching, E-Gear ratio selection, gain switching, position command
selection, position command trigger, motor stop, pulse input inhibit, event
trigger command, origin point, homing. E-Cam engaged.
Digital Output
ABZ Line driver output, Z open collector type output.
Torque limit reached, speed limit reached, servo ready, zero speed reached,
target position reached, target speed reached, servo alarm, servo warning,
homing is completed, overload level reached, internal position is attained,
position command overflows, software positive limit reached, software
reverse limit reached.
Analog input
Analog speed command/limit, Analog torque command/limit.
Analog output
Command pulse frequency, pulse deviation, current command,
DC bus
voltage, servo motor speed, motor torque value.
E
nv
ironmen
t
Temperature
0
℃
~ 55
℃
(
If the operating temperature is above 45˚C,
forced cooling is required)
Storage: -20~65
℃
(Non-freezing)
Humidity
Maximum 90% RH (Non-condensing)
Storage: below 90%RH (Non-condensing)
Installation site
Indoors (avoid direct sunlight), no corrosive vapor,
avoid flammable gases, fumes and dust.
Altitude
Altitude below 1000m
Vibration
Maximum 5.9m/s
2
Cooling method
Air convection cooling,
IP20.
Fan cooling, IP20.
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...