Torque command(%)
Input analog voltage(V)
Before offset voltage correction
After offset voltage correction
The offset voltage is set by PC27
6.2.3.
Torque command smoothing
This parameter is to set the filter time constant of torque command. With a proper filter time
constant value, you can run the servo motor smoothly even if a sudden change occurs. The
parameter description is as follows.
Name
Parameter
code
Setting
range
Unit
Default
value
Control
mode
Torque command filter
time constant
PB19
0~5000
ms
0
T