8. Parameters
8.1. Parameter definitions
From the perspective of safety and frequency of use, Shihlin drive parameters have below
types: basic parameters, gain and filter parameters, expansion parameters, and input/output
setting parameters. When you want to adjust parameter reading and writing permissions, you
can modify the setting of PA42 to change the setting of expansion parameters.
The following are the precautions of parameter setting.
1.
Parameter type classification
In section 8.2, parameters are classified into a parameter list according to its function, which
is for the users to use conveniently. For detailed parameter descriptions you can refer to
section 8.3.
2.
Special symbols for parameter codes
(■) the setting is vanished once power is off.
(*) the setting is valid after power cycling, such as PA01.
(▲) You are not able to set the parameter when Servo is ON, such as PA07. And there are 2
ways to switch off the servo.
(1)
Turn off the SON DI signal.
(2)
Set SON signal to 0 by changing PD16 , and ensure to restore PD16 after completion
of the modification.
Below is the group classification according to different functions.
Parameter group
Main content
Basic parameter
(No PA□□)
When the servo drive is used to perform position control, you need
to set these basic parameters.
Gain, filter parameter
(No PB□□)
When the servo drive is used to perform manual gain adjustment,
you need to set these parameters.
Expansion setting
parameter
(No PC□□)
This is the main parameter group used when speed control and
torque control mode is applied.
Input/output setting
parameter
(No PD□□)
Used to change the output/input signal of the servo drive.
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...