165
operation procedure, please refer to the table below.
When PB27 is set to 1 or 2, if the resonance still exists, please check whether one of the
parameters of PB02, PB22 and PB46 is 32. If yes, the resonance phenomenon cannot be
suppressed by the filter, and it is recommended to reduce the system bandwidth and perform
re-estimation. If it is less than 32 and greater than 0, it means that the automatic detection
mode has detected the resonance frequency, but the resonance still exists due to insufficient
attenuation rate (Note 1), you can manually increase the attenuation rate to improve (Note
2). If PB02, PB22 and PB46 are 0, it means that the resonance frequency is not detected,
which may due to the detection level (PB28) is too high, it is recommended to lower the level
and then set PB27 to 1 or 2 before performing detection again. The complete automatic
resonance suppression flow chart is as follows:
Note 1: the attenuation rate detected by the drive is the most suitable one, it may not be the
best one, but it can ensure the stable operation of the system.
Note 2: be careful when manually adjust the attenuation rate, if the setting is too large, it
may cause the system unstable.
PB27 parameter flow chart
PB27 current
value
PB27 modified
value
Function
0
1
Clear PB01~02, 21~22, 46~47 values,
enable auto-suppression function.
0
2
Clear PB01~02, 21~22, 46~47 values,
enable continuously auto-suppression function.
1
0
Store PB01~02, 21~22, 46~47 value,
disable auto-suppression function.
1
1
Clear PB01~02, 21~22, 46~47 values,
enable auto-suppression function.
1
2
Not clear PB01~02, 21~22, 46~47 values,
enable continuously auto-suppression function.
2
0
Store PB01~02, 21~22, 46~47 value,
disable auto-suppression function.
2
1
Clear PB01~02, 21~22, 46~47 values,
enable auto-suppression function.
2
2
Not clear PB01~02, 21~22, 46~47 values,
enable continuously auto-suppression function.
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...