167
Manual mode:
This servo drive provides two groups of suppression filters for users to manually operate,
the first group is PB31, PB32; the second group is PB33, PB34. In which, PB31 and PB33
are suppression frequencies, and PB32 and PB34 are suppression gains. If the vibration
frequency is known, the user can manually set the vibration frequency to PB31, PB33, and
set PB32, PB34 to 1. In these two parameters, set to 1 means to enable the suppression
function, and set to 0 is to disable the suppression function. If you want to improve the
position response, you can increase the gain value. The larger the value, the better the
response. (Note 1).
Auto mode:
The drive provides two groups of filters for users to perform automatic low-frequency
vibration suppression, the first group is PB31 and PB32; the second group is PB33 and
PB34. Among them, PB21 and PB25 are suppression frequencies, and PB22 and PB26
Name
Parameter
abbreviation
Parameter
code
Setting
range
Unit
Default
value
Control
mode
Auto vibration
suppression mode
AVSM
PB29
0~1
N/A
0
Pt, Pr
Low-frequency
vibration detection
level
VCL
PB30
1~8000 pulse
50
Pt, Pr
Low-frequency
vibration
suppression
frequency 1
VSF1
PB31
1~3000 0.1Hz
100
Pt, Pr
Low-frequency
vibration
suppression gain 1
VSG1
PB32
0~15
N/A
0
Pt, Pr
Low-frequency
vibration
suppression
frequency 2
VSF2
PB33
1~3000 0.1Hz
100
Pt, Pr
Low-frequency
vibration
suppression gain 2
VSG2
PB34
0~15
N/A
0
Pt, Pr
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...