174
Example 2: take deviation pulse as switching source
①
.
Relevant parameter setting
Name
Parameter
abbreviation
Parameter
code
Default
value
Unit
Servo motor load inertia ratio
GD1
PB06
10
0.1
times
Position loop gain
PG1
PB07
100
rad/s
Speed loop gain
VG1
PB08
500
rad/s
Speed integral gain
VIC
PB09
100
ms
Gain switching option
CDP
PB11
0003
N/A
Gain switching condition value
CDS
PB12
100
pulse
Gain switching time constant
CDT
PB13
10
ms
Servo motor load inertia ratio
2
GD2
PB14
20
0.1times
Position loop gain change
ratio
PG2
PB15
80
%
Speed loop gain change ratio
VG2
PB16
120
%
Speed integral gain change
ratio
VIC2
PB17
150
%
②
.
The gain switching diagram.
Gain change
Gain value after switching
Gain value
before switching
pulse errors
Pulse command
Pulse feedback
Name
CDP OFF
CDP ON
CDP OFF
Servo motor load inertia ratio
10
→
20
→
10
Position loop gain
100
→
80
→
100
Speed loop gain
500
→
600
→
500
Speed integral gain
100
→
150
→
100
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...