421
Address: 0x020B
Bit8~Bit15 Bit0
~
bit7
Bit number
DI11
DI12
Pin number
0x00~0x2F 0x00~0x2F Function code
Address: 0x020C
Bit8
~
bit15 Bit0
~
bit7
Bit number
DO2
DO1
Pin number
0x00~0x3F 0x00~0x3F Function code
Address: 0x020D
Bit8
~
bit15 Bit0
~
bit7
Bit number
DO4
DO3
Pin number
0x00~0x3F 0x00~0x3F Function code
Address: 0x020E
Bit8
~
bit15 Bit0
~
bit7
Bit number
DO6
DO5
Pin number
0x00~0x3F 0x00~0x3F Function code
(c)
Current control mode and servo status(Read-only)
Communication
address
Content
Data
length
0x0200
Bit0: servo ready status (0: Servo OFF, 1: Servo ON)
1word
0x0201
Bit0~Bit3: display current control mode of drive.
0: Pt position mode.
1: absolute Pr position
mode.
2: incremental Pr position
mode.
3: speed control mode.
4: torque control mode.
5: full-closed loop control
mode.
1word
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...