131
estimated automatically, you have to manually set PB06.
The related parameters setting are as follows:
Parameter
NO
Parameter
abbreviation
Parameter name
Modifiable or auto-
estimated
PA03
ATUL
Auto-tuning response
level setting
Modifiable
PB06
GD1
Servo motor Load inertia
ratio
Modifiable
PB07
PG1
Position loop gain
Auto-estimate
PB08
VG1
Speed loop gain
Auto-estimate
PB09
VIC
Speed integral gain
Auto-estimate
5.3.3.2 Auto tuning procedure
When the user sets the servo to auto-tuning mode, the servo action is showing in the following
block diagram.
motor
One touch
tuning
Auto setting
current
control
current feedback
response
level setting
turning on when set
to 2,3,4
load inertia ratio
estimation
position, speed feedback
inertia
estimation
parameter PB06
PA03
response
level
setting
auto-tuning mode
setting
auto-tuning process
PA02
load inertia
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...