9
1.5 Servo drive control modes introduction
Shihlin drive provides a variety of control modes for you, as detailed in the below table:
Mode name
Code
Description
S
in
g
le
m
o
d
e
Position mode
(terminal input)
Pt
Drive receives the external position pulse command which is
input from terminal and runs the motor to the target position.
Position mode
(internal
register)
Pr
The drive receives the position command which is provided by
the internal register (64 groups of registers). and runs the motor
to the target position. The DI signal can be used to select the
register number.
Speed mode
S
The drive receives the speed command and runs the motor to
the target speed. The speed command can be selected by the
DI signal to use analog voltage command or internal speed
command(7 groups of register).
Torque mode
T
The drive receives torque command which is provided by analog
voltage command or internal torque command, and runs the
motor to the target torque.
Multi-mode
Pt-S Pt/S is switched mutually via the signal of DI(LOP).
Pt-T Pt/T is switched mutually via the signal of DI(LOP).
Pr-S Pr/S is switched mutually via the signal of DI(LOP).
Pr-T Pr/T is switched mutually via the signal of DI(LOP).
S-T S/T is switched mutually via the signal of DI(LOP).
Pt-Pr Pt/Pr is switched mutually via the signal of DI(Pt-Pr).
Pt-Pr-S Pt/Pr/S is switched mutually via the signal of DI(LOP + Pt-Pr).
Pt-Pr-T Pt/Pr/T is switched mutually via the signal of DI(LOP + Pt-Pr).
Set PA01 to select the mode. After setting the parameter, restart the power to
activate the changed setting.
If use the default configuration directly, PA01 need set to 1XXX.
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...