292
No Abbr.
Parameter function and description
Mode Default Range Unit
PC01
STA
Acceleration time constant
The acceleration time is required when the motor
accelerates from 0 rpm to the rated motor speed,
which is defined as the acceleration time constant.
For example, if the servo motor rated speed is
3000 rpm, this parameter is set to 3000(3s). When
the speed command is set to 1000 rpm, it takes 1
second for the motor to accelerate from 0 rpm to
1000 rpm.
Please refer to section 6.4.3 for the instruction in
Pr mode. The acceleration time in JOG mode is
also set by this parameter.
S,
T
200
0
~
65550
ms
PC02
STB Deceleration time constant
The deceleration time is required when the motor
decelerates from rated speed to 0 rpm, which is
defined as the deceleration time constant. Please
refer to section 6.4.3 for the instruction in Pr mode.
The deceleration time in JOG mode is also set by
this parameter.
S,
T
200
0
~
65550
ms
PC03
STC S-curve acceleration /deceleration time constant
During acceleration/deceleration, a three-stage
acceleration/deceleration curve is applied to
provide smooth processing. An appropriate STC
setting can improve the stability of the motor when
starting and stopping.
In order to make the command curve smoother,
Pr,
S,
T
0
0
~
10000
ms
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...