279
No
Abbr.
Parameter function and description
Mode
Default
Range
Unit
PB04
PST Position command filter time constant
This parameter is to set the filter time constant of
position command. With an appropriate setting,
the motor can run smoothly when the servo drive
encounters a sudden change of position
command.
The actual time to reach the target position is 5
times of PST.
Pt,Pr
3
0
~
20000
ms
PB05
FFC Position feed-forward gain
If the system runs smoothly in position mode,
increasing the feed-forward gain value will
reduce the position tracking errors. If the system
has resonated in position mode, decreasing the
gain value will reduce mechanical vibration.
Pt,Pr
0
0
~
200
%
PB06
GD1 Servo motor load inertia ratio
This parameter is to set ratio of load inertia to
servo motor inertia. When PA02= 1 which is set to
auto gain tuning mode 1, it will set PB06
automatically.
★
When set to Linear motor drive(PL01=1), the
range is 0 ~ 65535.
All
70
0
~
1200
or
65535
0.1
times
0.1kg
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...
Страница 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...